We'd appreciate your feedback. Send feedback Subscribe to our newsletters and alerts


Journal of Orthodontic and Periodontal Research

2023 Volume 3

Comparative Evaluation of Accuracy of Implants Placed with Thermoplastic and Three‑Dimensional‑Printed Surgical Guides: A Randomized Controlled Trial


,
  1. Department of Oro-Maxillofacial Surgery and Stomatology, Semmelweis University, Budapest, Hungary.
  2. Department of Oral Biology, Semmelweis University, Budapest, Hungary.
Abstract

The current study was planned to evaluate the accuracy of dental implant placement with two different types of surgical guides: Thermoplastic and three‑dimensional (3D) printed. A total of 32 implants were placed in 20 healthy, partially dentate individuals with an isolated single missing tooth. The implant sites were randomly allocated into two treatment groups: Group A (thermoplastic implant surgical guide, n = 16 implants) and Group B (3D printed implant surgical guide, n = 16 implants). All the cases in both groups were digitally planned according to a defined protocol, and a comparison of the planned and actual implant positions was performed using the medical image analysis software. The differences in the outcome variables, i.e., angular deviation (AD), 3D error at the entry, 3D error at the apex (3D EA), vertical deviation (VD), and composite deviation, were statistically analyzed. All the outcome variables showed improvements, but statistically significant improvement was shown by AD (P = 0.005), 3D EA (P = 0.01), and VD (P = 0.007). The mean and standard deviation (SD) for AD, (3D EA), and VD were 5.58° ±1.93°, 0.96 ± 0.32 mm, and 0.58 ± 0.36 mm, respectively, for group A. The mean and SD for AD, (3D EA), and VD were 3.94° ± 0.64°, 0.64 ± 0.35 mm, and 0.29 ± 0.13 mm, respectively, for group B (P < 0.05). Within the limits of the study, dental implants placed using 3D‑printed surgical guides were positioned clinically with greater accuracy, and fewer deviations were observed from their presurgical planned positions as compared to the thermoplastic surgical guides.


How to cite this article
Vancouver
Suhail H, Bihari E. Comparative Evaluation of Accuracy of Implants Placed with Thermoplastic and Three‑Dimensional‑Printed Surgical Guides: A Randomized Controlled Trial. . 2023;3:190-202.
APA
Suhail, H., & Bihari, E. (2023). Comparative Evaluation of Accuracy of Implants Placed with Thermoplastic and Three‑Dimensional‑Printed Surgical Guides: A Randomized Controlled Trial. Journal of Orthodontic and Periodontal Research, 3, 190-202.

About GalaxyPub

Find out more

Galaxy Publication is an independent scholarly publishing platform operating under the scientific and organizational designation of Eshragh Scientific and Research Center and the legal framework of ISRAK PUBLISHER EGITIM HIZMETLERI LIMITED.

The publisher is committed to ethical, transparent, and high-quality academic publishing and supports scholarly communication through internationally aligned editorial practices, publication ethics, and responsible dissemination of scientific research.