We'd appreciate your feedback. Send feedback Subscribe to our newsletters and alerts


Journal of Orthodontic and Periodontal Research

2023 Volume 3

Comparative Evaluation of Accuracy of Implants Placed with Thermoplastic and Three‑Dimensional‑Printed Surgical Guides: A Randomized Controlled Trial


,
  1. Department of Oro-Maxillofacial Surgery and Stomatology, Semmelweis University, Budapest, Hungary.
  2. Department of Oral Biology, Semmelweis University, Budapest, Hungary.
Abstract

The current study was planned to evaluate the accuracy of dental implant placement with two different types of surgical guides: Thermoplastic and three‑dimensional (3D) printed. A total of 32 implants were placed in 20 healthy, partially dentate individuals with an isolated single missing tooth. The implant sites were randomly allocated into two treatment groups: Group A (thermoplastic implant surgical guide, n = 16 implants) and Group B (3D printed implant surgical guide, n = 16 implants). All the cases in both groups were digitally planned according to a defined protocol, and a comparison of the planned and actual implant positions was performed using the medical image analysis software. The differences in the outcome variables, i.e., angular deviation (AD), 3D error at the entry, 3D error at the apex (3D EA), vertical deviation (VD), and composite deviation, were statistically analyzed. All the outcome variables showed improvements, but statistically significant improvement was shown by AD (P = 0.005), 3D EA (P = 0.01), and VD (P = 0.007). The mean and standard deviation (SD) for AD, (3D EA), and VD were 5.58° ±1.93°, 0.96 ± 0.32 mm, and 0.58 ± 0.36 mm, respectively, for group A. The mean and SD for AD, (3D EA), and VD were 3.94° ± 0.64°, 0.64 ± 0.35 mm, and 0.29 ± 0.13 mm, respectively, for group B (P < 0.05). Within the limits of the study, dental implants placed using 3D‑printed surgical guides were positioned clinically with greater accuracy, and fewer deviations were observed from their presurgical planned positions as compared to the thermoplastic surgical guides.


How to cite this article
Vancouver
Suhail H, Bihari E. Comparative Evaluation of Accuracy of Implants Placed with Thermoplastic and Three‑Dimensional‑Printed Surgical Guides: A Randomized Controlled Trial. . 2023;3:190-202.
APA
Suhail, H., & Bihari, E. (2023). Comparative Evaluation of Accuracy of Implants Placed with Thermoplastic and Three‑Dimensional‑Printed Surgical Guides: A Randomized Controlled Trial. Journal of Orthodontic and Periodontal Research, 3, 190-202.

About GalaxyPub

Find out more

Our esteemed publisher is committed to advancing medical knowledge through rigorous research dissemination. We exclusively accept submissions related to the field of medicine.

Our journals provide a platform for clinicians, researchers, and scholars to share groundbreaking discoveries, clinical insights, and evidence-based practices. By maintaining this specialized focus, we ensure that their publications contribute significantly to the advancement of healthcare worldwide.