We'd appreciate your feedback. Send feedback Subscribe to our newsletters and alerts


Journal of Orthodontic and Periodontal Biomaterials Research

2023 Volume 3 Issue 2

Electron Microscopic Evaluation of Compatibility of Various Attachment Designs Used in Clear Aligner Therapy


, , , , ,
  1. Department of Oral Biology, College of Dental Medicine, University of Mumbai, Mumbai, Sri Lanka.
Abstract

The effectiveness of clear aligner therapy depends significantly on the precision of force delivery through the aligner–attachment interface. This study aimed to evaluate the microscopic compatibility between different orthodontic clear aligner materials (Duran+ and Zendura FLX) and attachment designs (rectangular and optimized) using scanning electron microscopy (SEM).  Fifty-six samples were divided into four groups: rectangular attachments with Duran+ aligners (n = 14), rectangular attachments with Zendura FLX aligners (n = 14), optimized attachments with Duran+ aligners (n = 14), and optimized attachments with Zendura FLX aligners (n = 14). Attachments were bonded to bovine incisors using standardized protocols. Clear aligners were thermoformed at 220 °C for 40 s. Cross-sectional samples were analyzed using SEM at 250× magnification. Gap measurements were taken at seven points for rectangular attachments and five points for optimized attachments.  Gap measurements ranged from 14.75 ± 1.41 µm to 91.07 ± 3.11 µm. Zendura FLX demonstrated significantly better adaptation than Duran+ with rectangular attachments (42.10 ± 1.07 µm vs. 44.52 ± 1.51 µm, p < 0.001). Optimized attachments showed better overall adaptation than rectangular attachments. All combinations showed regional variation with the largest gaps at gingival borders (67.18–91.07 µm) and the smallest at flat buccal surfaces (14.75–20.98 µm).  Perfect adaptation was not achieved with any material–attachment combination tested. Material selection and attachment design significantly influence microscopic adaptation, with multi-layer materials and optimized geometries showing superior performance. These findings provide mechanical explanations for clinical limitations in clear aligner therapy.


How to cite this article
Vancouver
Iyer F, Hussain SL, Gupta PP, Patel U, Iyer U, Iyer RS. Electron Microscopic Evaluation of Compatibility of Various Attachment Designs Used in Clear Aligner Therapy. . 2023;3(2):1-14.
APA
Iyer, F., Hussain, S. L., Gupta, P. P., Patel, U., Iyer, U., & Iyer, R. S. (2023). Electron Microscopic Evaluation of Compatibility of Various Attachment Designs Used in Clear Aligner Therapy. Journal of Orthodontic and Periodontal Biomaterials Research, 3(2), 1-14.
Scan to access this article
View Full HTML Download PDF
Downloads: 22

Views: 70
Share Article:

About GalaxyPub

Find out more

Our esteemed publisher is committed to advancing medical knowledge through rigorous research dissemination. We exclusively accept submissions related to the field of medicine.

Our journals provide a platform for clinicians, researchers, and scholars to share groundbreaking discoveries, clinical insights, and evidence-based practices. By maintaining this specialized focus, we ensure that their publications contribute significantly to the advancement of healthcare worldwide.