This investigation explores the biomechanical response of titanium mini-implants (Ti6Al4V) subjected to various orthodontic loading conditions using finite element analysis (FEA). The purpose is to assess their strength, fatigue resistance, and structural reliability under clinically relevant forces. Appropriate force magnitudes are essential for maintaining implant durability and preventing deleterious stress transmission to surrounding bone tissues. A standard titanium MI (2.0 mm in diameter, 12 mm in length) was modeled and analyzed in an FEA framework. The mandibular structure was reconstructed from computed tomography (CT) data using SpaceClaim 2023.1 and meshed into 10-node tetrahedral elements in ANSYS Workbench. Material constants were defined based on published data, and the bone–implant interface was simulated through a nonlinear frictional contact model. Orthodontic loads of 2 N and 10 N, each applied at a 30° inclination, were tested to replicate actual treatment conditions. Mechanical outputs—including total deformation, von Mises stress, equivalent strain, fatigue life, and safety factors—were examined to evaluate overall implant performance. At a load of 2 N, displacement was minimal (0.0328 mm), and the model sustained approximately 445,000 loading cycles within safe fatigue limits, maintaining a safety factor of 4.8369. Under a 10 N load, however, the implant endured only 1546 cycles before predicted failure, accompanied by increased stress (6.468 × 10⁵ MPa) and concentrated strain zones—suggesting a higher likelihood of structural failure and bone overload. The simulations identified a force threshold beyond which mechanical stability and peri-implant health deteriorate. Findings confirm that maintaining orthodontic forces near 2 N maximizes implant lifespan and preserves bone integrity. Conversely, excessive loads (around 10 N) drastically shorten service life and raise the risk of mechanical or biological complications. These outcomes underscore the importance of carefully calibrated force application to enhance the efficiency and longevity of orthodontic mini-implants.


How to cite this article
Vancouver
Mokoena KV, Mensah AU, Mokoena F, Nkosi G, Ndiaye K. Impact of Force Control Strategies on the Stability of Orthodontic Mini-Implants. . 2025;5(1):93-102.
APA
Mokoena, K. V., Mensah, A. U., Mokoena, F., Nkosi, G., & Ndiaye, K. (2025). Impact of Force Control Strategies on the Stability of Orthodontic Mini-Implants. Journal of Orthodontic and Periodontal Biomaterials Research, 5(1), 93-102.
Articles
Effect of Stabilization Discs on Orthodontic Mini-Implant Success: An Experimental Study
Journal of Orthodontic and Periodontal Biomaterials Research
Vol 5 Issue 1, 2025 | Miguel J. Castillo
Nickel Ion Release from Nickel-Containing Orthodontic Archwires: A Narrative Review of Experimental and Clinical Evidence
Journal of Orthodontic and Periodontal Biomaterials Research
Vol 2 Issue 2, 2022 | Balazs H. Varga
Interprofessional Collaboration between Orthodontists and Oral Hygienists: Findings from a Survey Study
Journal of Orthodontic and Periodontal Biomaterials Research
Vol 4 Issue 1, 2024 | Kenji S. Sato
Effect of Fiber Reinforcement on Microleakage and Fatigue Resistance of Composite Restorations
Journal of Orthodontic and Periodontal Biomaterials Research
Vol 2 Issue 1, 2022 | Erik J. Svensson
Awareness and Perceptions of Periodontal–Systemic Relationships Among Dental Practitioners
Journal of Orthodontic and Periodontal Biomaterials Research
Vol 2 Issue 1, 2022 | Yousef X. Khalil
Clinical Competence in Orthodontic Diagnosis among Final-Year Dental Students: An Evaluative Study
Journal of Orthodontic and Periodontal Biomaterials Research
Vol 5 Issue 2, 2025 | Noura Haddad
Preventive Strategies for White Spot Lesions Associated with Fixed Orthodontic Appliances: A Review
Journal of Orthodontic and Periodontal Biomaterials Research
Vol 5 Issue 2, 2025 | Lucie F. Kaczmarek
Nickel Ion Release from Orthodontic Archwires: A Narrative Review of Experimental and Clinical Studies
Journal of Orthodontic and Periodontal Biomaterials Research
Vol 5 Issue 2, 2025 | Naledi D. Diallo
Comparative Evaluation of Mandibular Kinematics in Orthodontic Patients Using Optical Jaw Tracking Technology
Journal of Orthodontic and Periodontal Biomaterials Research
Vol 5 Issue 2, 2025 | Camila P. Ramirez
Cytotoxic and Endocrine Disrupting Effects of Removable Orthodontic Retainer Materials: A Comprehensive Review
Journal of Orthodontic and Periodontal Biomaterials Research
Vol 5 Issue 2, 2025 | Usman Singh
Educational Impact of 3D-Printed Cleft Lip and Palate Phantom Models in Undergraduate Orthodontic Training
Journal of Orthodontic and Periodontal Biomaterials Research
Vol 5 Issue 2, 2025 | Pavel C. Kaczmarek
Scan to access this article
View Full HTML Download PDF
Downloads: 29

Views: 60
Share Article:

About GalaxyPub

Find out more

Our esteemed publisher is committed to advancing medical knowledge through rigorous research dissemination. We exclusively accept submissions related to the field of medicine.

Our journals provide a platform for clinicians, researchers, and scholars to share groundbreaking discoveries, clinical insights, and evidence-based practices. By maintaining this specialized focus, we ensure that their publications contribute significantly to the advancement of healthcare worldwide.