We'd appreciate your feedback. Send feedback Subscribe to our newsletters and alerts


Journal of Orthodontic and Periodontal Biomaterials Research

2025 Volume 5 Issue 2

Electron Microscopic Evaluation of Attachment Design Compatibility in Clear Aligner Therapy


,
  1. Department of Orthodontics and Dentofacial Orthopedics, Faculty of Health Sciences, University of Auckland, Auckland, United Kingdom.
  2. Department of Dental Public Health, School of Medicine and Dentistry, University of Sydney, Sydney, United Kingdom.
Abstract

The clinical effectiveness of clear aligners hinges on how accurately forces are transmitted through the interface between aligners and attachments. This study aimed to investigate the microscopic fit between two types of aligner materials—Duran+ and Zendura FLX—and two attachment designs, rectangular and optimized, using scanning electron microscopy (SEM). Fifty-six attachment–aligner samples were prepared and divided evenly into four groups: rectangular attachments with Duran+ (n = 14), rectangular with Zendura FLX (n = 14), optimized with Duran+ (n = 14), and optimized with Zendura FLX (n = 14). Attachments were bonded to bovine incisors following a standardized protocol, and aligners were thermoformed at 220 °C for 40 seconds. Cross-sections were examined under SEM at 250× magnification, and gaps between aligner and attachment were measured at multiple points (seven for rectangular, five for optimized). Gap sizes ranged from 14.75 ± 1.41 µm to 91.07 ± 3.11 µm. Zendura FLX exhibited significantly closer adaptation compared with Duran+ in rectangular attachments (42.10 ± 1.07 µm vs. 44.52 ± 1.51 µm, p < 0.001). Overall, optimized attachments achieved better microscopic fit than rectangular designs. Across all groups, the largest gaps were observed at gingival margins (67.18–91.07 µm), whereas the smallest were found on flat buccal surfaces (14.75–20.98 µm). Perfect contact between aligners and attachments was not observed for any combination. Both material type and attachment geometry play crucial roles in microscopic adaptation, with multi-layered aligner materials and optimized designs demonstrating superior conformity. These results provide insight into the mechanical reasons behind certain limitations in clinical clear aligner performance.


How to cite this article
Vancouver
Hughes HT, Hughes H. Electron Microscopic Evaluation of Attachment Design Compatibility in Clear Aligner Therapy. . 2025;5(2):1-13.
APA
Hughes, H. T., & Hughes, H. (2025). Electron Microscopic Evaluation of Attachment Design Compatibility in Clear Aligner Therapy. Journal of Orthodontic and Periodontal Biomaterials Research, 5(2), 1-13.
Articles
Effect of Stabilization Discs on Orthodontic Mini-Implant Success: An Experimental Study
Journal of Orthodontic and Periodontal Biomaterials Research
Vol 5 Issue 1, 2025 | Miguel J. Castillo
Nickel Ion Release from Nickel-Containing Orthodontic Archwires: A Narrative Review of Experimental and Clinical Evidence
Journal of Orthodontic and Periodontal Biomaterials Research
Vol 2 Issue 2, 2022 | Balazs H. Varga
Interprofessional Collaboration between Orthodontists and Oral Hygienists: Findings from a Survey Study
Journal of Orthodontic and Periodontal Biomaterials Research
Vol 4 Issue 1, 2024 | Kenji S. Sato
Effect of Fiber Reinforcement on Microleakage and Fatigue Resistance of Composite Restorations
Journal of Orthodontic and Periodontal Biomaterials Research
Vol 2 Issue 1, 2022 | Erik J. Svensson
Awareness and Perceptions of Periodontal–Systemic Relationships Among Dental Practitioners
Journal of Orthodontic and Periodontal Biomaterials Research
Vol 2 Issue 1, 2022 | Yousef X. Khalil
Clinical Competence in Orthodontic Diagnosis among Final-Year Dental Students: An Evaluative Study
Journal of Orthodontic and Periodontal Biomaterials Research
Vol 5 Issue 2, 2025 | Noura Haddad
Preventive Strategies for White Spot Lesions Associated with Fixed Orthodontic Appliances: A Review
Journal of Orthodontic and Periodontal Biomaterials Research
Vol 5 Issue 2, 2025 | Lucie F. Kaczmarek
Nickel Ion Release from Orthodontic Archwires: A Narrative Review of Experimental and Clinical Studies
Journal of Orthodontic and Periodontal Biomaterials Research
Vol 5 Issue 2, 2025 | Naledi D. Diallo
Comparative Evaluation of Mandibular Kinematics in Orthodontic Patients Using Optical Jaw Tracking Technology
Journal of Orthodontic and Periodontal Biomaterials Research
Vol 5 Issue 2, 2025 | Camila P. Ramirez
Cytotoxic and Endocrine Disrupting Effects of Removable Orthodontic Retainer Materials: A Comprehensive Review
Journal of Orthodontic and Periodontal Biomaterials Research
Vol 5 Issue 2, 2025 | Usman Singh
Educational Impact of 3D-Printed Cleft Lip and Palate Phantom Models in Undergraduate Orthodontic Training
Journal of Orthodontic and Periodontal Biomaterials Research
Vol 5 Issue 2, 2025 | Pavel C. Kaczmarek
Scan to access this article
View Full HTML Download PDF
Downloads: 24

Views: 59
Share Article:

About GalaxyPub

Find out more

Our esteemed publisher is committed to advancing medical knowledge through rigorous research dissemination. We exclusively accept submissions related to the field of medicine.

Our journals provide a platform for clinicians, researchers, and scholars to share groundbreaking discoveries, clinical insights, and evidence-based practices. By maintaining this specialized focus, we ensure that their publications contribute significantly to the advancement of healthcare worldwide.